Friedrich EP08G11B Specifications Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
(B)
(A)
(C)
Front
SIDE VIEW
Friedrich room air conditioners are designed to operate in outdoor temperatures from 60°
F to 115°
F.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
() models
meet the ENERGY STAR
®
guidelines for energy efciency.
The consumer- through the AHAM Room Air Conditioner Certication Program- can be certain that the AHAM Certication
Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efciency ratio.
Specifications
EnErgy Star
®
qualied
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
Sleeve P1 does not have thru-the-wall hole dimensions, as these units are xed chassis and should not be installed thru-the-wall.
NOTE: S,M and L sleeves may be installed in window with no side kits if properly installed.
Installation Information/Sleeve Dimensions
Sleeve Dimensions Drawing
Room_Air_Conditioners_Chill_Submittal_2014
MODEL Cooling Btu Heating Btu
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
Energy
Efciency
Ratio
EER
Estimated
Yearly
Operating
Cost COP
Moisture
Removal-
Pints/HR CFM Sleeve
Net
Wt.
Ship
Wt.
Chill
CP05G10A 5450 - 115 4.8 500 - - 10.7 $46 - 1.5 140 P1 46 50
CP06G10A 6000 - 115 4.9 530 - - 11.2 $48 - 1.8 200 P6 60 66
CP08G10A 7800 - 115 6.3 690 - - 11.2 $63 - 2.2 250 P6 64 70
CP10G10A 10000 - 115 8.5 880 - - 11.3 $80 - 3.0 300 P7 81 87
CP12G10A 12000 - 115 9.7 1060 - - 11.3 $96 - 3.3 330 P7 87 93
CP15G10A 15000 - 115 12.0 1330 - - 11.2 $121 - 4.0 400 P8 120 134
CP18G30A 18000/17500 - 230/208 7.3/7.8 1600/1560 - - 11.2/11.2 $145 - 4.5 520 P9 136 150
CP24G30A 23500/23000 - 230/208 10.9/11.8 2390/2340 - - 9.8/9.8 $216 - 6.8 590 P9 146 160
Chill+
®
(Electric Heat)
EP08G11A 8000 3850 115 7.5 820 11.0 1260 9.8 $73 - 2.6 265 P7 79 85
EP12G33A 12000/11500 11200/9200 230/208 5.5/5.8 1220/1170 15.3/14.0 3500/2900 9.8/9.8 $110 - 3.3 265 P7 87 93
EP18G33A 18000/17500 12000/9800 230/208 8.3/9.0 1850/1800 16.0/15.0 3670/3100 9.7/9.7 $167 - 5.5 430 P9 136 150
EP24G33A 23500/23000 12000/9800 230/208 12.2/13.2 2760/2700 16.0/15.0 3670/3100 8.5/8.5 $249 - 6.5 560 P9 146 160
LISTED
ROOM AIR CONDITIONERS
183H
Sleeve
Height
INCHES
Width
INCHES
Depth
with Front
INCHES
Shell Depth
to Louvers
INCHES
Minimum
Extension
Into Room*
INCHES
Minimum
Extension
Outside
*
INCHES
Window Width
INCHES
In-wall Installation
Finished Hole
INCHES
Carton Dimensions
INCHES
Minimum** Maximum Height Width Max. Depth
Height Width Depth
P1 12"
18
½"
15" 5"
3
½"
10
¾"
20
1
/8
36" NOT FOR THRU-WALL 15
1
/
4
22
1
/
4
17
1
/
2
P6 14” 18
3
/8
20
7
/8
8
1
/8
4
½"
11" 20
1
/8
36" 14
1
/8
18
7
/8
7 ½" 17
7
/8
22
3
/
4
22”
P7 15" 23
5
/8
"
21
¾
8
¾"
4
½"
12 25 ¼ 39" 15 ¼" 23
7
/8
8" 18
3
/
4
26
3
/
4
23
7
/
8
P8 16
7
/8
26" 26
7
/8
10
1
/4
"
5
½"
16
5
/8
"
26
½
"
42" 17
1
/8
26 ¼" 9 " 21
1
/
2
29
1
/
2
29”
P9
16
7
/8
26" 30
3
/8
10
1
/4
5
½"
19
½"
26
½
"
42" 17
1
/8
26 ¼" 9 “ 21
1
/
2
33 28
7
/
8
Model
Circuit Rating
Breaker or
T-D Fuse
Plug Face
(NEMA#)
Power Cord
Length (ft.)
Wall Outlet
Appearance
CP05G10A 125V-15A 5 -15P 6 1/2
CP06G10A, CP08G10A, CP10G10A,
CP12G10A and CP15G10A. EP08G11A.
125V - 15A 5- 5P 6
CP18G30A 250V - 15A 6 - 15P 4 1/2
CP24G30A.
EP12G33A, EP18G33A and EP24G33A.
250V - 20A 6 - 20P 4
Circuit Rating/Breaker
Page view 1
1 2

Comments to this Manuals

No comments