- 63 -
Only for training and service purposes
Check Point
1. Check the Input Voltage (L1- L2 230V±10%)
2. Check Input Voltage Sensor output voltage (2.5Vdc±10%)
25
Input voltage
• Abnormal Input voltage
(140Vac , 300Vac)
• Check the power source.
• Check the components.
Display
code
Title Cause of error Check point & Normal condition
Is Inverter PCB Normal?
No
Replace inverter PCB assembly
Is input voltage normal ?
No
Check L~N Voltage is 230V±15%
Yes
< Input Power Source Check Point >
Recheck power and
installation condition
Yes
n Error Diagnosis and Countermeasure Flow Chart