Filter Information
The !lter in your Friedrich removes dust, pollen and other
impurities from the air as they are drawn through the unit.
The !lter is permanent and reusable, and has a germicidal
treatment which is not affected by washing.
Wont Cool
If the unit operates, but doesnt cool, check to see that the con-
trols are properly set. Inspect the !lter and clean it thoroughly, if
needed. Check to see if the chassis seal gasket is installed (refer
to installation instructions).
Wont Run
If the unit does not operate at all, check that the power supply
connections are tight. Check for blown fuses or tripped circuit
breakers. Replace blown fuses with the proper size time-delay
fuse. The nameplate on the unit shows the proper fuse size. After
restoring power, wait three minutes before restarting the unit.
Inside Coil Freezes Up
Your FriedrichHazardgard isdesigned not to freezewith outdoor
temperatures as low as 45°F (C). Freezing should only occur
when the outside air is damp and below 45°F (7°C). If the indoor
Maintenance Checklist
coil should ice over whilecooling, set the thermostat tothe warm-
estposition until theiceon the coil is gone. Setting the thermostat
to a slightly warmer position will probably keep ice from forming
on the coil. A dirty !lter will contribute to icing.
Cleaning
The front grille of your Friedrich, as well as the complete cabi-
net may be cleaned with warm water and a mild detergent. The
coils and base pan should be cleaned periodically for the most
ef!cient operation. We suggest you call your Friedrich dealer
for this service.
Lubrication
Fan motors are factory lubricated and sealed. No lubrication
is required.
A clogged, dirty !lter reduces the air "ow through the unit and
reduces its ef!ciency. You should check the !lter every seven
to ten days, depending on the amount your unit is used. Clean
the !lter regularly.
FILTER RETAINER CLIPS
The
lter can be removed for cleaning by opening the front of
the unit and releasing the
lter from its retaining clips.