Friedrich C24YJ User Manual Page 72

  • Download
  • Add to my manuals
  • Print
  • Page
    / 90
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 71
- 72 -
Only for training and service purposes
39
Transmission Error
Between (PFC Micom
INV Micom)
Communication Error
Between PFC Micom
and INV Micom.
1. Micom defect/Circuit defect
2. Different Micom S/W Version
3. ODU inverter PCB assembly damage
Display
code
Title Cause of error Check point & Normal condition
n Error Diagnosis and Countermeasure Flow Chart
Is Inverter PCB assembly normal?
No
Replace inverter PCB assembly
Is PFC Micom & INV Micom
S/W Program normal?
No
Upgrade Micom Program
Yes
Yes
Recheck power and installation condition
Page view 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 89 90

Comments to this Manuals

No comments