Friedrich MC12Y3JM Brochure Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
MULTIZONE CONFIGURATIONS
OUTDOOR SYSTEM COMPONENTS
MODEL
NUMBER
Btu COOLING
Min. / Nom / Max.
REVERSE CYCLE
HEAT Btu
Min. / Nom / Max. VOLTAGE HEIGHT WIDTH DEPTH
MR24DY3JM 8,400 / 20,000 / 25,000 9,240 / 24,000 / 28,800 208/230 31 13/16 34 1/4 12 5/8
MR36TQY3JM 10,978 / 36,000 / 37,400 12,418 / 36,000 / 45,100 208/230 45 7/8 35 7/16 14 9/16
MR24DY3JMA 10,800 / 20,000 / 25,000 11,880 / 24,000 / 28,800 208/230 25 3/4 34 1/4 12 5/8
MR36TQY3JMA 10,800 / 32,000 / 38,400 11,880 / 36,000 / 41,600 208/230 32 7/8 37 3/8 13
MR48DEY3JM 14,400 / 48,000 / 58,000 15,840 / 54,000 / 61,000 208/230 54 11/32 37 13/32 15 3/4
INDOOR SYSTEM COMPONENTS
MODEL
NUMBER Btu COOLING
REVERSE
CYCLE
HEAT Btu VOLTAGE
Rated
Amps
LINE SIZE
DISCHARGE
O.D. (IN.)
LINE SIZE
SUCTION
O.D. (IN.) HEIGHT WIDTH DEPTH
Wall-mounted Units
MW07Y3JM 7000 8100 230 0.20 1/4" 3/8" 11-1/4 34-7/8 8-1/4
MW09Y3J 9000 10800 230 0.40 1/4" 3/8" 11-1/4" 35-1/4" 8-1/4"
MW12Y3J 11200 13300 230 0.40 1/4" 3/8" 11-1/4" 35-1/4" 8-1/4"
MW18Y3J 17000 20200 230 0.40 1/4" 1/2" 12-7/8" 40-5/8" 9-5/8"
Ceiling Cassettes
MC12Y3JM 12000 13800 230 0.25 1/4" 3/8" 8-7/16" 22-7/16" 22-7/16"
MC18Y3JM 18000 19000 230 0.25 1/4" 1/2" 10-3/32” 22 7/16" 22-7/16"
The Insider™ Concealed Ducted Components
MD09Y3JM 9000 10400 230 0.40 1/4" 3/8" 7-15/32" 27 9/16" 27 9/16"
MD12Y3JMA 12000 13800 230 0.40 1/4" 3/8" 7-15/32" 32-9/32" 22 5/8"
MD18Y3JMA 18000 20800 230 0.40 1/4" 1/2" 7-15/32" 43-5/16” 22 5/8"
Friedrich
Model
Number
AHRI
Reference
Number IndoorType
System
Capacity EER SEER
High
Heat
47F HSPF
Low
Heat
17F
MR24DY3JMA
8915232 Non-ducted Indoor Units 20000 13.50 21.70 24000 10.60 14500
8915233 Ducted Indoor Units 17800 11.50 17.50 22400 9.80 14000
8915234 Mixed Ducted and Non-ducted Indoor Units 18900 12.50 19.60 23200 10.20 14250
MR36TQY3JMA
8915235 Non-Ducted Indoor Units 32000 13.00 22.00 36000 10.00 20000
8915236 Ducted Indoor Units 28000 11.00 18.20 34000 9.70 19500
8915240 Mixed Ducted and Non-ducted Indoor Units 30000 12.00 20.10 35000 9.85 19750
MR48TQY3JM
8915237 Non-Ducted Indoor Units 48000 12.50 19.50 54000 10.00 35000
8915238 Ducted Indoor Units 44000 10.80 17.50 50000 9.70 33600
8915239 Mixed Ducted and Non-ducted Indoor Units 46000 11.65 18.50 52000 9.85 34300
31
Page view 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36

Comments to this Manuals