Manual Changeover
Non-Programmable
Hardwired
RT4
Non-Programmable Electronic Thermostat
Installation, Operation & Application Guide
For use with Friedrich PTAC and Vert-I-Pak Systems
30-Minute Power Loss Memory Retention
Page view 0
1 2 3 4 5 6 ... 12 13

Summary of Contents

Page 1 - Hardwired

Manual ChangeoverNon-Programmable HardwiredRT4Non-Programmable Electronic ThermostatInstallation, Operation & Application Guide• For use with Frie

Page 2 - Table of Contents

8caution!: Do not switch system to cool if the outdoor temperature is below 50°F (10°C). This can damage the air conditioning system and may cause per

Page 3 - Parts Diagram

9Wiring DiagramNOTE: B terminal used on heat pump models onlyCRWYBGCRWYBOGTHERMOSTATFRIEDRICHPTACHARDWIRED

Page 4 - Important Safety Information

10TroubleshootingSymptom RemedyThe system is not turning on Check the wiring (see Installation, Page 4)LCD is blank Check the wiring (see Installation

Page 5 - General Description

Friedrich Air Conditioning Co.Post Office Box 1540 • San Antonio, Texas 78295-15404200 N. Pan Am Expressway • San Antonio, Texas 78218-5212(210) 357-4

Page 6 - To Install Thermostat

Table of ContentsParts Diagram ...

Page 7

1Parts DiagramMode Switch Fan SwitchCelsius/Fahrenheit JumperReset ButtonHeat Pump/Non-Heat Pump JumperGas/Electric SwitchF–CNON–HP HPCool HeatOffOnAu

Page 8 - Replacing Wiring Labels

2SpecificationsInput: • Voltage: 18-30 VAC Output: • Maximum: 1 amp per terminal (3 amp total for all terminals)Temperature Ranges: • Temperature c

Page 9 - Operation

3Package Contents/Tools RequiredPackage includes: RT4 non-programmable thermostat on base, thermostat cover, wiring labels, screws and wall anchors,

Page 10 - A Quick Test

4ELECTRICAL SHOCK HAZARD – Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the OFF posit

Page 11 - HARDWIRED

5To Install Thermostat (continued)4. Put thermostat base against the wall where you plan to mount it (Be sure wires will feed through the wire openin

Page 12 - Troubleshooting

6Replace the old labels with the enclosed new labels:Replacing Wiring LabelsOld New TypeF, G G Fan control relayB B Heat active reversing valveY, Y6 Y

Page 13

7Setting the Room Temperature (Setpoint Temperature)Step 1: Press the or button; the current temperature setpoint displays. Step 2: Press the or